Columns/YMC*Gel
YMC-BioPro IEX Columns are for proteins and peptides, based on a newly developed hydrophilic polymer with low nonspecific absorption.
YMC-BioPro IEX Columns are available in QA and SP chemistries on 5 µm porous (QA and SP columns) and non-porous (QA-F and SP-F columns) hydrophilic polymer beads packed in biocompatible PEEK column housings in a variety of dimensions (inquire for details).
Please note that the same QA and SP chemistries are also available on 75 µm porous polymer beads supplied in bulk - See separate datasheet.
| YMC-BioPro QA | YMC-BioPro QA-F | YMC-BioPro SP | YMC-BioPro SP-F | |
| Matrix | Hydrophilic Polymer Bead | |||
| Particle size | 5µm | |||
| Pore size | 1000 Å | Non-porous | 1000 Å | Non-porous |
| Charged group | -CH2N+(CH3)3 | -CH2CH2CH2SO3- | ||
| Counter ion | Cl - | Na + | ||
| Ion-exchange capacity |
0.075 - 0.100 meq/mL resin |
0.075 - 0.110 meq/mL resin |
0.070 - 0.095 meq/mL resin |
0.230 - 0.290 meq/mL resin |
| Dynamic binding capacity |
> 110 mg BSA/mL resin |
> 12 mg BSA/mL resin |
> 70 mg human IgG/mL resin |
> 10 mg human IgG/mL resin |
| pH Range | 2.0 - 12.0 | |||
| Column Housing Material |
PEEK | |||
For information and specifications covering BioPro 75 µm materials,
see separate datasheet.
Features:
- QA and SP chemistry
- Hydrophilic polymer bead
- Porous and Non-porous types
- Low operating pressure
Benefits:
- Excellent resolution
- High recovery of biomolecules
- Ultra-fast analysis on non-porous type
![]() |
1. Ribonuclease Å (0.1 mg/mL)
|
||||||||||||||||||
![]() |
|||||||||||||||||||
| YMC-BioPro SP-F can separate the proteins sharply without peak-tailing observed on Brand T. Furthermore, despite larger particle size, the theoretical plate number of YMC-BioPro is higher than that of Brand T. | |||||||||||||||||||
Comparison of dynamic binding capacity (DBC) and recovery
| Dynamic binding capacity (mg/mL-gel, 10% breakthrough) |
Eluted amount (mg/mL-gel) |
Recovery* (%) |
|
| YMC-BioPro QA (5 µm, 50 x 4.6 mml.D.) | 125 | 120 | 95 |
| Brand G (10 µm, 50 x 5.0 mml.D.) | 100 | 35 | 35 |
| Brand T (10 µm, 50 x 4.6 mml.D.) | 73 | 58 | 79 |
* Recovery: (Eluted amount / Dynamic binding capacity) x 100
Compared with convential porous-polymer anion-exchange column, YMC-BioPro QA scores the superior DBC and recovery rate. Thus YMC-BioPro shows the least nonspecific absorption in conventional columns.
Comparison of the effect of sample load on YMC-BioPro QA and commercial Q type product
![]() |
![]() |
|||||||||||||||
|
YMC-BioPro QA shows the excellent peak shapes even when the loading amount increases. By contrast, the column of Brand G cannot separate well even in small amounts of injection. |





