Columns/YMC*Gel

YMC-UltraHT series
Specification
Particle size : 2µm
Pore size : 120Å
Carbon contents
  Pro C18
  Hydrosphere C18

: :

16%
12%
Usable pH range : 2.0-8.0
Application Data

YMC-UltraHT series columns are specifically designed for high-speed and high-throughput analysis. YMC-UltraHT series has two products, Pro C18 as our standard ODS and Hydrosphere C18 for hydrophilic compounds. Both of them show the same selectivity and superior peak shapes as 3µm and 5µm Pro series, so an easy method transfer from conventional HPLC to ultra-fast LC is available without changing elution conditions.

  • Pro C18 as standard, and Hydrosphere C18 for hydrophilic compounds.
  • Superior column performance at higher flow rate and higher pressure.
  • Speed-up and cost-cutting for the analysis.
  • Applicable to both conventional HPLC and specific ultra pressure system.
  • Simple method transfer from conventional HPLC.
  • Excellent resolution with back pressure less than that of sub-2µm.


Characteristics of 2μm packing material

Van Deemter curves/Column pressure
Column : 50 X 2.0 or 2.1 mml.D.
Eluent : acetonitrile/water (60/40)
Temperature : 25°C
Sample : Butyl benzoate


YMC-UltraHT series shows the same efficiency as sub-2μm columns for ultra-fast LC system and reduces the system pressure significantly.



Reduced analysis time and cost

conventional method:YMC-UltraHT Pro C18 50 X 2.0 mmI.D. 2µm

Flabonoids

  1. Myricetin
  2. Quercetin
  3. Apigenin
  4. Kaempferol
  5. Baicalein
  6. Chrysin
  7. Acacetin
Column : acetonitrile/water/formic acid (35/65/0.1)
Temperature : 40ºC
Detection : UV at 260 nm


This example shows the conversion of a traditional HPLC method to one using a YMC-UltraHT column. Since the performance is not decrease even when the flow rate is 3 times as fast as the conventional condition, it can be shorten analysis time 90% without losing the separation characteristics.


The great separation characteristics and peak shapes by well-known Pro series

sub-2µm ODS(Brand I7)(Brand L4)

Alkaloids

  1. Scopolamine
  2. Atropine
  3. Cinchonine
  4. Quinine
  5. Dihydroquinine
Column : 50 X 2.0 or 2.1 mmI.D.
Eluent :

20mM CH3COOH-CH3COONH4(pH 4.9) /acetonitrile(80/20)

Flow rate : 0.6 mL/min
Temperature : 40ºC
Detection : UV at 220 nm


During the separation of alkaloids (basic compounds), YMC-UltraHT Pro C18 exhibits great peak shapes with much less tailing compared to commercial silica-based sub-2μm columns.


Ultra-fast separation for hydrophilic compounds - Hydrosphere C18

2µm YMC-UltraHT Hydrosphere C18

Organic solvent metabolites
in urine (as standard)

  1. Creatinine
  2. Mandelic acid
  3. Phenylglyoxylic acid
  4. Hippuric acid
  5. o-Methylhippuric acid
  6. p-Methylhippuric acid
  7. m-Methylhippuric acid
Column : 50 X 2.0 or 2.1 mmI.D.
Eluent :

20mM CH3COONH4/IPA (97/3)

Flow rate : 0.4 mL/min
Temperature : 35ºC
Detection : UV at 225 nm
Injection : 1µL


YMC-UltraHT Hydrosphere C18 is able to strongly retain metabolites that conventional silica-based sub-2μm columns cannot separate well.

3% of organic solvent is used, but Hydrosphere C18 can be used with high reproducibility even under 100% aqueous condition.


Selecting the desired column dimensions

Feature and Use For LC/MS or reduction of solvent usage
(2.0 mmI.D.)
For conventional LC system
(3.0 mmI.D.)
Emphasize reduction of
analysis time
(length: 30 mm)
30 X 2.0 -
Ultra-fast separation with the
similar property as traditional
column.
(length: 50 mm, 75 mm)
Standard for Ultra-fast LC
50 X 2.0
50 X 3.0
75 X 2.0 75 X 3.0
High resolution column for
closely eluting peaks
(length: 100 mm)
100 X 2.0 100 X 3.0



Multicomponent separation by 100mm column

Peptide mapping

YMC-UltraHT Pro C18 100 X 2.0 mmI.D. 2µm PC=185

Eluent : A) water/TFA(100/0.1)
B) acetonitrile/TFA(100/0.1)  5-50%B(0-15 min)
Flow rate : 0.4 mL/min
Temperature : 37ºC
Detection : UV at 220 nm
Injection : 1µL
Sample : Tryptic digest of β-Lactogloblin B (5 mg/mL; 37 ℃, 24 hr)


YMC-UltraHT column can resolve 38% more peaks than a conventional 5μm column with increased sensitivity.


Easily applicable for conventional LC system: 3.0mmI.D.

50 X 3.0 mmI.D. / 50 X 2.0 mmI.D.

Cephalosporin antibiotics

  1. Cephalexin
  2. Cefaclor
  3. Cephaloglycin
  4. Cephaloridine
Column : YMC-UltraHT Pro C18
Eluent :

acetonitrile/20mM KH2PO4 (10/90)

Temperature : 37ºC
Detection : UV at 260 nm


YMC-UltraHT series can be used for fast analysis with conventional LC system, as its pressure is lower than conventional sub-2μm column. Considering the extra column band broadening, the column of 3.0 mmI.D. is more applicable for conventional LC system than the column of 2.0 mmI.D.