SFC Columns

YMC delivers 11 different phases for SFC separations giving the chemist good choices for SFC achiral separations.

  • SFC columns11 different phases
  • Analytical or Prep
  • Columns with 3, 5, or 10 micron packings
  • YMC's hallmark attention to particle and chemistry details

Analytical 4.6 x 25 cm columns packed with 5 um particles are listed below.  Please inquire for columns packed with 3 and 10 um packings and preparative version of the below  listed columns.

The stationary phases used in YMC SFC columns are specially formulated for SFC use, but are subject to the same rigorous chemical and physical property standards that have been the hallmark of YMC HPLC columns for decades.

SFC can offer some advantages over HPLC for similar applications.   The low viscosity of supercritical carbon dioxide allows for analytical separations 3-5 times faster that those for normal phase HPLC.  Speed of the SFC separations, conservation of organic solvents, and more concentrated product fractions make SFC a desirable preparative chromatographic technique for purifying chemical mixtures.

All YMC SFC columns are packed specifically for use in SFC, and are tested under SFC conditions.

Column Selection

Phase Column Size Part Number Description
2-ethyl pyridine 4.6 x 250 mm EP06S05-2546PS 5 micron, 60Å
Diol 4.6 x 250 mm DP06S05-2546PS 5 micron, 60Å
Diol 4.6 x 250 mm DL12S05-2546PS 5 micron, 120Å
diethylaminopropyl 4.6 x 250 mm DE06S05-2546PS 5 micron, 60Å
pyridine amide 4.6 x 250 mm PY06S05-2546PS 5 micron, 60Å
propyl acetamide 4.6 x 250 mm PP06S05-2546PS 5 micron, 60Å
silica 4.6 x 250 mm SL12S05-2546PS 5 micron, 120Å
Polyamine II 4.6 x 250 mm PB12S05-2546PS 5 micron, 120Å
amino 4.6 x 250 mm NH12S05-2546PS 5 micron, 120Å
cyano 4.6 x 250 mm CN12S05-2546PS 5 micron, 120Å
PVA-Sil 4.6 x 250 mm PV12S05-2546PS 5 micron, 120Å

Column Selectivity

Every application is different. To illustrate the selectivity behavior of the different phases we used a standard mix of common pharmaceutical compounds and separated them under otherwise identical conditions on eight of the columns in the table above.

Separation Conditions:

Modifier : Methanol w/0.1% Diethylamine
Gradient Elution : 5% modifier - 65% modifier over 12.5 minutes
Flow Rate : 3.5 mL/min
Outlet Pressure : 150 bar
Column Temp. : 40°C
Detection : 230 nm
Injection Volume : 5µL
Particle size of material : 5µm
Pore size of material : 120Å, except as noted
Column Dimensions : 250 x 4.6mm


Analytes:

  1.   Citral
  2.   Lidocaine
  3.   Caffeine
  4.   Amitriptyline
  5.   Ibuprofen
  1.   Propanolol
  2.   Procainamide
  3.   Sulpride
  4.   Cytosine
  5. Sulfinprazone